Check the condition of the cables along the Z‑axis assembly
WHAT YOU NEED
Safety Equipment:Standard Personal Protective Equipment
Other Equipment:Step Ladder
CAUTIONSHARP BLADE: Keep clear of the saw blade while working inside the saw chamber.
- Using the Manual Mode window, move the Y-axis to the middle position and the Z-axis to the lowest position.
- Press the E‑stop button on the operator console.
- Open the saw chamber door.
- Open up the dome.
-
Inspect the following cables for any signs of damage:
- the cables connected to the saw head junction box
- the cables connected to the slip ring
- the cables connected to the Z‑axis junction box
- the cables connected to the Z‑axis motor
- the cables in the cable tray and cable chain
- Inspect the cable tray and cable chain for any damaged or broken parts that may cause rubbing on the cables.
- Remove any bits of timber that may cause damage to the cables.